HR-1300E
Measurement Range: E -200 to 800°C
HOLD
The thermometer stops measurement
by the HOLD key and holds the present readings.
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
Resolution change
Press the [RESO] key to change the resolution of readings.
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
Calibration
The displayed value can be adjusted the CAL SET key.
Alarm output
The thermometer gives an alarm when readings go beyond the high or low limits.
Model | HR-1300 | ||
Display | LCD | ||
Waterproof specifications | - | ||
Input connector | ASP | ||
Input type | Thermocouple Input: Type E, K | ||
Channel | 1ch | ||
Signal source resistance | MAX.1k ohm | ||
Measurement Range | 1°C Resolution | E | -200 to 800°C |
K | -200 to 1370°C | ||
0.1°C Resolution | E |
-104.9 to 504.9°C (Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) |
|
K |
-104.9 to 504.9°C (Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.) |
||
Measurement Accuracy | 1°C Resolution | 0°C to | ± (0.1% of reading +1°C) |
to 0°C | ± (0.5% of reading +1°C) | ||
0.1°C Resolution | 0°C to | ± (0.05% of reading + 0.2°C) | |
to 0°C | ± (0.15% of reading + 0.2°C) | ||
Reference junction compensation accuracy | ±0.2°C at 25°C±10°C | ||
Temperature Coefficient*1 |
±0.02×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.3°C is added at room temp. of 0°C or 50°C) |
||
Operation Environment |
0 to 50°C, 0 to 80%RH (Non condensing) |
||
Storage Environment |
-20 to 50°C, 0 to 85%RH (Non condensing) |
||
Battery life | approx.600h | ||
Power supply(Dry battery) | 4 AA Alkaline batteries | ||
Power supply(AC power) option | available | ||
Sampling rate | approx.200ms | ||
Linearlizer | Digital Linearizer method (Compliant with JIS C1602-2015) | ||
Dimensions(mm) | approx. 82(w)×166(H)×36(D) [Protruded parts excluded] | ||
Weight | approx. 350g [Include Batteries] | ||
Supplied accessories | Manual,Test report,Soft case, | ||
Hand strap,4 AA Alkaline batteries | |||
Optional accessories | Alarm output cable | ||
Alarm output | TABLE1 | ||
Compatible standards |