Fluke 87V
From the control room to the factory, the Fluke 80 Series digital multimeter has earned a reputation as a digital multimeter that industrial engineers and technicians trust. When production efficiency needs to be ensured, the Fluke 80 Series delivers the accuracy and advanced troubleshooting capabilities you need to solve problems quickly.
Use the low-pass filter function to accurately measure voltage and frequency on noisy devices such as inverters. Use the peak capture function to detect intermittent and overvoltage problems in just 250 microseconds (µs).
Electrical safety
All inputs are protected according to the second edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000V. They can withstand voltage spikes up to 8,000V and reduce the risks associated with overvoltage and voltage surges (spikes).
Accurately measure the pulse width of inverter motor signals
Until now, no multimeter has been able to accurately measure inverter devices. However, the new Fluke 87V is specifically designed to handle these complex signals. Think about the potential productivity you will achieve by troubleshooting inverter systems without having to guess. Always measure accurately.
Here are the technical specifications for the Fluke 87V multimeters:
**DC Voltage**
- Maximum voltage: 1000V
- Accuracy: Fluke 87V: ±(0.05%+1)
- Maximum resolution: Fluke 87V: 10 µV
**AC Voltage**
- Maximum voltage: 1000V
- Accuracy: Fluke 87V: ±(0.7%+2) true RMS
- AC current frequency range: Fluke 87V: 20kHz* (*with low-pass filter; 3db at 1kHz)
- Maximum resolution: 0.1 mV
**DC Current**
- Maximum current: 10A (maximum of 20A for up to 30 seconds)
- Current accuracy: Fluke 87V: ±(0.2%+2)
- Maximum resolution: Fluke 87V: 0.01 µA
**AC Current**
- Maximum current: 10A (maximum of 20A for up to 30 seconds)
- Current accuracy: Fluke 87V: ±(1.0%+2) true RMS
- Maximum resolution: 0.1 µA
**Resistance**
- Maximum resistance: 50 MΩ
- Accuracy: Fluke 87V: ±(0.2%+1)
- Maximum resolution: 0.1Ω
**Capacitance**
- Maximum capacitance: 9,999 µF
- Accuracy: ±(1%+2)
- Maximum resolution: 0.01 nF
**Frequency**
- Maximum frequency: 200 kHz
- Accuracy: ±(0.005%+1)
- Maximum resolution: 0.01 Hz
**Duty Cycle**
- Maximum duty cycle: 99.9%
- Accuracy: ±(0.2%/kHz +0.1%)
- Maximum resolution: 0.1%